Dr Alberto Bellone, Reference Physician, Ophthalmology Functional Unit, Casa di Cura Sedes Sapientiae (Humanitas Group), Turin
For the EyeMax Mono intraocular lens (SharpView Ophthalmology), the manufacturer sets a limit: the maculopathy must stay within 10° of the foveal centre. Those 10° are a radius, not a diameter: about 3 mm of retina, or 2 disc diameters. In clinic, however, the lesion is measured in millimetres. The calculator converts that measurement into degrees, giving the value to enter in the manufacturer’s official selector.
With a patient who has maculopathy, the question that most often stalls selection is whether the lesion exceeds 10°. Visual acuity cannot answer it: it measures the best remaining point of retina, not the extent of the damage. I needed a repeatable method based on the tests we already perform in clinic.
It is not a service offered to the public, nor a CE-marked medical device: it is a study tool I developed for my own work. I make it available on request to fellow ophthalmologists who wish to study the method. The decision to implant remains with the manufacturer’s official selector and the surgeon’s judgement.
To receive the password, write to me at occhiobellone@gmail.com.